alert8: any-match critical hardware/power alarms (dying_gasp, ONU
config/HAL/info failures, PSU/memory/ASIC faults, cold start) - same
fire-on-every-occurrence philosophy as alert4_juniper_chassis_alarm.
alert9: repeated-warning threshold on severity_tag:warning, grouped by
device+event_type, >5 in 5min - same philosophy as
alert7_accelppp_repeated_error_warn (a single occurrence can be
transient; repetition means a real problem). Covers signal degradation,
low optical power, BGP/LACP flapping, DDoS/SNMP violations, etc.
Deliberately excludes purely informational event_types (logins,
config_saved, ONU registration, alarm-cleared/recovery events) to avoid
noise.
Not yet verified live - same caveat as the rule27-84 commit, the test
container is still unreachable.
- step_pipeline_rules() and step_pipelines() only ever created new
rules/pipelines by title, never updated existing ones whose content
changed under the same title. Confirmed live this session: 5 new rules
were added to rules/*.json and created fine in Graylog, but "Servers
Parsing"'s stage list was never updated to actually call them, since
the pipeline already existed. Both functions now compare by 'source'
content and PUT-update if it differs, matching the pattern already used
elsewhere (e.g. step_inputs()'s timezone self-heal).
- alert7's query (vendor:accel-ppp) was too broad: it also matches
routine traffic tagged only by the generic accelppp_interface_tag
fallback rule, which sets vendor but never event_type - producing false
"(Empty Value)" group_by matches on ordinary volume. Confirmed live.
Fixed to vendor:accel-ppp AND event_type:* - severity_tag was
considered instead but rejected, since accelppp_router_address_error
(the rule that inspired this alert) never set it either.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Analyzed a real 1GB accel-ppp log (2026-07-23): only 2,819 of its lines
were error:/warn:, and one pattern - "can't determine router address" -
repeated 2,746 times over ~4 hours for two specific subscriber interfaces
before self-resolving, completely unalerted since no alert covered it.
- New pipeline rules for 3 previously-unclassified real message types
(radius:dm_coa session not found, mac change detected, dhcpv4 short
packet) plus a text-based fallback pair (accelppp_unclassified_error/
warn) for anything not yet specifically classified - needed because
Vector-shipped accel-ppp lines have no real syslog PRI header, so the
numeric-severity generic_critical_severity rule never fires for this
source.
- New alert7: group by gl2_remote_ip + event_type, fires on >5 occurrences
in 5 minutes - low enough to have caught the real incident within its
first cycle, high enough to tolerate a single transient warning.
- vector-accel-ppp-setup.md gained a "keep only error/warn" filter option
(Step 2b), explicitly documented as a deliberate tradeoff: it also drops
RADIUS accounting, so the Servers & Sessions dashboard and session
correlation go empty for any server that applies it. Both the
with-filter and without-filter full configs are included so the choice
is per-server, not global.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
The alert5 description and both READMEs said "~4,600-4,800 msgs/10min" as
the calibrated baseline - a transcription error, a digit short of the real
figure (~46,000-48,000/10min, matching the ~278k/hour number right next to
it, which was correct). The configured threshold (150,000) was actually
computed from the correct number, so no behavior changed - only the
description text was wrong.
Also documents a real event from today: EX-NAS-1-2's first-ever Vector
startup tripped this alert (430,982 msgs/10min) - Vector's file source
replays existing log content from the beginning with no checkpoint yet, so
a busy log's backlog shows up as a single burst rather than a real ongoing
issue. Confirmed the sample messages were all routine DHCP/session churn
timestamped around the same moment.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
- Two flood-detection alerts (per-source message volume, calibrated live
against real traffic) grouped by gl2_remote_ip
- Session correlation: accelppp_interface fallback tagging plus
radius_session_id/calling_station_id/radius_username extraction, so a
subscriber's full session lifecycle is searchable by one key
- Replace the single combined dashboard with three focused ones (Overview
& Alerts, Network Equipment, Servers & Sessions)
- Propagate GRAYLOG_ROOT_TIMEZONE and IP-in-alerts fixes into the reusable
install script and templates
- Add a Forgejo Actions workflow (manual trigger) that re-runs
install-graylog.sh on a self-hosted runner living in the container,
automating the deploy step this project has done by hand all along
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>